Name:100W/52V Desktop Power Adapter(With Certification)

Model:GWS-AP100-52C

100W/52V Desktop Power Adapter(With Certification)

Name:
Information:
Email:
Telephone:
Company:
Code:

  Submit
  • Overview

  • Specification

  • Download


Product Name100W/52V Desktop Power Adapter(With Certification)
ModelGWS-AP100-52C
Group of Output1
DC Voltage52V
Default Output Voltage 0-1.92A
Ripple Noise0<Ta≤55℃,≤50mVp-p ;-15≤Ta≤0℃,≤100mVp-p
Stabilized Voltage Precision±1%
Line Regulation±1%
Load Regulation ±1%
Temperature Coefficient±0.03%/℃
Output Start Time≤3.0S (120Vac input, Full load); ≤2.0S (220Vac input, Full load)
Output Hold Time≥10mS(120Vac input, Full load); ≥20mS(220Vac input, Full load)
Voltage Overshoot <5.0%
Input Voltage Range90~264VAC
Input Rated Voltage Range100~240VAC
Frequency Range47Hz~63Hz
Efficiency ≥89%
Input Current <0.82A
Inrush Starting Current <40A@300Vac Cold start;
Leakage Current input to output less than 0.25mA
Over Power Protection120~150W Swing machine (Testing method: Increase the output current until enabling the protection. Protection mode:Swing machine, Self-recovery after over-power released.)
Over Voltage Protection59-60V Swing machine (Short circuit the Pin1-2 of U8, swing machine. Output recovery to normal after removing the short circuit) Note: Do not use external voltage.
Over Current Protection2.304~2.88A Swing machine (Testing method: Increase the output current until enabling the protection. Protection mode:Swing machine, Self-recovery after over-current released.)
Short Circuit ProtectionIt can be short circuited for a long time and automatically recover after the short circuit is eliminated.
Operation Temperature and Humidity-20℃~65℃; 20%~90%RH No condensing
Storage Temperature and Humidity-40℃~85℃; 5%~95%RH non-condensing
LibrationFrequency range: 10 ~ 500Hz, Acceleration: 2G, Each sweep cycle 10min. Six sweeps along the X, Y, and Z axis
Security StandardGB4943/EN60950
Dielectric StrengthInput—Output:3KVac/10mA; Input--Case:1.5KVac/10mA; Output---Case:0.5KVDC/10mA Time for each testing is 1min.
Insulation ResistanceInput-Output: 100M ohms; Input-Case: 100M ohms; Output-Case: 100M ohms;
Electromagnetic Interference EN55022 Class A
Harmaonic Current IEC61000-3-2 class A equipment requirements
Electromagnetic interference Immunity EN61000-4-2,4,5,6,8,11 ENV50204, class A heavy industry standard
Design MTBF 100,000Hrs AT 25℃, MIL-217 Method 2 Components Stress Method
Product size(L*W*H) 141*60.5*31.5mm
Certification 3C.CE. FCC.EMI/EMC
NotesIf the specification is not specified, all specifications and parameters shall be measured at rated input, rated load and 25 C ambient temperature. Ripple noise test method: the use of a 12# twisted pair, while the terminal to parallel capacitance of 0.1uF and 10uF, measured at the scope of the oscilloscope 20MHz bandwidth. The power supply will be installed on the final equipment as a component, and the final equipment will still have to meet the EMC condition.
Top
  • E-mail:onv@onv.com.cn

  • WeChat