Name:120W/48V Industrial DIN Rail Power Supply

Model:GWS-DP120-48

120W/48V Industrial DIN Rail Power Supply

Name:
Information:
Email:
Telephone:
Company:
Code:

  Submit
  • Overview

  • Specification

  • Download

120W/48V Industrial DIN Rail Power Supply

GWS-DP120-48 is one economical slim 120W industrial DIN Rail power supply series, adapting to be installed on TS-35/7.5 or TS-35/15 mounting rails. The entire series adopts the full range AC input from 90VAC to 264VAC and conforms to EN61000-3-2, the norm the European Union regulates for harmonic current.

GWS-DP120-48 is designed with metal housing that enhances the unit’s power dissipation. With working efficiency up to 89%, the entire series can operate at the ambient temperature between -40to 70under air convection. It is equipped with constant current mode for over load protection, fitting various inductive or capacitive applications. The complete protection functions and relevant certificates for industrial control apparatus make GWS-DP120-48 a very competitive power supply solution for industrial applications.





Product Name120W/48V Industrial DIN Rail Power Supply120W/24V Industrial DIN Rail Power Supply
ModelGWS-DP120-48GWS-DP120-24
Group of Output11
DC Voltage48V24V
Default Output Voltage48.00-48.2V (Vin: 220VAC / LOAD: 0A)24.00-24.2V (Vin: 220VAC / LOAD: 0A)
Output Rated Current2.5A5A
Output Current Range0-2.5A0-5A
Output Rated Power 120W120W
Total Peak Output Power Up to 180W(Sustainable time 10S/220VAC)Up to 180W(Sustainable time 10S/220VAC)
Peak Output Current3.5A( Sustainable time 10S/220VAC)7.5A( Sustainable time 10S/220VAC)
Ripple noisePeak - Peak ≤100mV (Test Method: The terminal shall be in parallel with capacitance of 0.1uF and 47uF, testing at 20MHz)Peak - Peak ≤100mV (Test Method: The terminal shall be in parallel with capacitance of 0.1uF and 47uF, testing at 20MHz)
Output Regulation Range @25℃46~56V22.5~28V
Stabilized Voltage Precision±1% (@ 90-264Vac input, 100% load)±1% (@ 90-264Vac input, 100% load)
Line Regulation±0.5% (@ 90-264Vac input, 100% load)±0.5% (@ 90-264Vac input, 100% load)
Load Regulation±1% (@ 90-264Vac input, 100% load)±1% (@ 90-264Vac input, 100% load)
Temperature Coefficient±0.03%/℃±0.03%/℃
Output Start Time< 2S @ nominal input (100% load )< 1S @ nominal input (100% load )
Output Hold Time> 20ms @ 115Vac, > 50 ms @ 230Vac (100% load )> 20ms @ 115Vac, > 115 ms @ 230Vac (100% load )
Voltage Overshoot≤5%≤5%
Input Voltage Range90~264VAC90~264VAC
Input Rated Voltage Range100~240VAC100~240VAC
Frequency Range47Hz~63Hz47Hz~63Hz
Starting Voltage90Vac90Vac
Efficiency> 90.0% @ 115Vac, > 91.0% @ 230Vac> 90.0% @ 115Vac, > 91.0% @ 230Vac
Input Current< 2.20A @ 115Vac, < 1.10A @ 230Vac< 2.20A @ 115Vac, < 1.10A @ 230Vac
Inrush Starting Current< 35A @ 115Vac & 230Vac< 35A @ 115Vac & 230Vac
Power Factor @25℃> 0.99 @ 115Vac, > 0.93 @ 230Vac> 0.99 @ 115Vac, > 0.93 @ 230Vac
Over Power Protection144~180W Swing machine (Testing method: Increase the output current until enabling the protection. Protection mode:Swing machine, Self-recovery after over-power released.144~180W Swing machine (Testing method: Increase the output current until enabling the protection. Protection mode:Swing machine, Self-recovery after over-power released.
Over Voltage Protection57~70V Swing machine (Short circuit the Pin1-2 of U8, swing machine. Output recovery to normal after removing the short circuit) Note: Do not use external voltage.30~36V Swing machine (Short circuit the Pin1-2 of U8, swing machine. Output recovery to normal after removing the short circuit) Note: Do not use external voltage.
Over Current3~3.75A Swing machine (Testing method: Increase the output current until enabling the protection. Protection mode:Swing machine, Self-recovery after over-current released.)6~7.5A Swing machine (Testing method: Increase the output current until enabling the protection. Protection mode:Swing machine, Self-recovery after over-current released.)
Short Circuit ProtectionIt achieves the long-term short circuit by connecting a sufficient cross-sectional area copper cable (Length at 15cm±5cm) with power output port. Self-recovery to normal after removing the short circuit.It achieves the long-term short circuit by connecting a sufficient cross-sectional area copper cable (Length at 15cm±5cm) with power output port. Self-recovery to normal after removing the short circuit.
Operation Temperature and Humidity-40~70℃; 20%~95%RH-40~70℃; 20%~95%RH
Storage Temperature and Humidity-40℃~85℃; 10%~95%RH non-condensing-40℃~85℃; 10%~95%RH non-condensing
LibrationFrequency range: 10 ~ 500Hz, Acceleration: 2G, Each sweep cycle 10min. Six sweeps along the X, Y, and Z axisFrequency range: 10 ~ 500Hz, Acceleration: 2G, Each sweep cycle 10min. Six sweeps along the X, Y, and Z axis
SurgeAcceleration: 20G, Duration time: 11mS, Three shocks along X, Y and Z axisAcceleration: 20G, Duration time: 11mS, Three shocks along X, Y and Z axis
Altitude2000m2000m
Security StandardGB4943/EN60950 ■Reference □CertificationGB4943/EN60950 ■Reference □Certification
Dielectric StrengthInput—Output:3KVac/10mA; Input--Case:1.5KVac/10mA; Output---Case:0.5KVDC/10mA Time for each testing is 1min.Input—Output:3KVac/10mA; Input--Case:1.5KVac/10mA; Output---Case:0.5KVDC/10mA Time for each testing is 1min.
Grounding TestTest Condition: 32A/2min; Ground bond: <0.1 ohms.Test Condition: 32A/2min; Ground bond: <0.1 ohms.
Leakage CurrentInput to GND ≤3.5mA; Input to output ≤0.25mA (Input 264Vac, 63Hz)Input to GND ≤3.5mA; Input to output ≤0.25mA (Input 264Vac, 63Hz)
Insulation ResistanceInput—Output: 10M ohms;Input—Output: 10M ohms;
Conducted InterferenceEN55022, EN55024, FCC PART 15 CLASS BEN55022, EN55024, FCC PART 15 CLASS B
Radiated InterferenceEN55022, EN55024, FCC PART 15 CLASS BEN55022, EN55024, FCC PART 15 CLASS B
Harmaonic currentEN61000-3-2 CLASS DEN61000-3-2 CLASS D
Conducted EmissionEN61000-4-6 Level3EN61000-4-6 Level3
Radiated EmissionEN61000-4-3 Leve3 criterion BEN61000-4-3 Leve3 criterion B
Power Frequency EmissionEN61000-4-8 Level3EN61000-4-8 Level3
Electrostatic EmissionEN61000-4-2 Level4 criterion BEN61000-4-2 Level4 criterion B
EFTEN61000-4-4 Level4 criterion BEN61000-4-4 Level4 criterion B
SurgeEN61000-4-5 Level4 criterion BEN61000-4-5 Level4 criterion B
Dip and InterruptionEN61000-4-11EN61000-4-11
Dimension/Weight134*124*41mm / 580g134*124*41mm / 580g