Name: 240W/24V Industrial DIN Rail Power Supply

Model:GWS-DP240-24

240W/24V Industrial DIN Rail Power Supply

Name:
Information:
Email:
Telephone:
Company:
Code:

  Submit
  • Overview

  • Specification

  • Download

240W/24V Industrial Din RailPower Supply


GWS-DP240-24 is one economical slim 240W industrial DIN Rail power supply series, adapting to be installed on TS-35/7.5 or TS-35/15 mounting rails. The entire series adopts the full range AC input from 90VAC to 264VAC and conforms to EN61000-3-2, the norm the European Union regulates for harmonic current.

GWS-DP240-24 is designed with a metal shell, which is easy to increase the heat dissipation of the machine. The working efficiency is as high as 90%. The product can work in -40℃ to 70℃ambient temperature under the condition of air circulation. It has a constant current mode overload protection function and is suitable for various Inductive or capacitive load applications, complete protection functions and compliance with industrial control equipment certifications, making GWS-DP240-24 a very competitive power solution for industrial applications.




Product Name 240W/24V Industrial DIN Rail Power Supply
ModelGWS-DP240-24
Group Of Output 1
DC Voltage 24VDC
Default Output Voltage 0-10A
Ripple Noise 0<Ta≤55℃,≤50mVp-p;-15≤Ta≤0℃,≤100mVp-p
Stabilized Voltage Precision ±1%
Line Regulation ±1%
Load Regulation ±1%
Temperature Coefficient ±0.03%/℃
Output Start Time ≤3.0S (120Vac input, Full load); ≤2.0S (220Vac input, Full load)
Output Hold Time ≥10mS(120Vac input, Full load); ≥20mS(220Vac input, Full load)
Voltage Overshoot <5.0%
Input Voltage Range 90VAC~264VAC
Input Rated Voltage Range100VAC~240VAC
Frequency Range 47Hz~63Hz
Efficiency 91%
Input Current <2.2A
Inrush Starting Current <40A@300Vac Cold start
Leakage Current input to output less than 0.25mA
Over Power Protection288~360W Swing machine (Testing method: Increase the output current until enabling the protection. Protection mode:Swing machine, Self-recovery after over-power released.)
Over Voltage Protection28-29V Swing machine (Short circuit the Pin1-2 of U8, swing machine. Output recovery to normal after removing the short circuit) Note: Do not use external voltage.
Over Current Protection12~15A Swing machine (Testing method: Increase the output current until enabling the protection. Protection mode:Swing machine, Self-recovery after over-current released.)
Short Circuit ProtectionIt can be short circuited for a long time and automatically recover after the short circuit is eliminated.
Operation Temperature And Humidity -40℃~70℃; 20%~90%RH No condensing
Storage Temperature And Humidity -40℃~85℃; 5%~95%RH No condensing
Security Standard GB4943/EN60950
Dielectric StrengthInput—Output:3KVac/10mA; Input--Case:1.5KVac/10mA; Output---Case:0.5KVDC/10mA Time for each testing is 1min.
Insulation ResistanceInput-Output: 100M ohms; Input-Case: 100M ohms; Output-Case: 100M ohms
Electromagnetic Interference EN55022 Class A
Harmaonic Current IEC61000-3-2 class A equipment requirements
Electromagnetic interference Immunity EN61000-4-2,4,5,6,8,11 ENV50204, class A heavy industry standard
Design MTBF 100,000Hrs AT 25℃, MIL-217 Method 2 Components Stress Method
Dimensions (W*H*D) 130.5*124*45mm
NotesIf the specification is not specified, all specifications and parameters shall be measured at rated input, rated load and 25 C ambient temperature. Ripple noise test method: the use of a 12# twisted pair, while the terminal to parallel capacitance of 0.1uF and 10uF, measured at the scope of the oscilloscope 20MHz bandwidth. The power supply will be installed on the final equipment as a component, and the final equipment will still have to meet the EMC condition.
Top
  • E-mail:onv@onv.com.cn

  • WeChat