240W/24V Industrial DIN Rail Power Supply
240W/24V Industrial Din RailPower Supply
GWS-DP240-24 is one economical slim 240W industrial DIN Rail power supply series, adapting to be installed on TS-35/7.5 or TS-35/15 mounting rails. The entire series adopts the full range AC input from 90VAC to 264VAC and conforms to EN61000-3-2, the norm the European Union regulates for harmonic current.
GWS-DP240-24 is designed with a metal shell, which is easy to increase the heat dissipation of the machine. The working efficiency is as high as 90%. The product can work in -40℃ to 70℃ambient temperature under the condition of air circulation. It has a constant current mode overload protection function and is suitable for various Inductive or capacitive load applications, complete protection functions and compliance with industrial control equipment certifications, making GWS-DP240-24 a very competitive power solution for industrial applications.
Product Name | 240W/24V Industrial DIN Rail Power Supply |
Model | GWS-DP240-24 |
Group Of Output | 1 |
DC Voltage | 24VDC |
Default Output Voltage | 0-10A |
Ripple Noise | 0<Ta≤55℃,≤50mVp-p;-15≤Ta≤0℃,≤100mVp-p |
Stabilized Voltage Precision | ±1% |
Line Regulation | ±1% |
Load Regulation | ±1% |
Temperature Coefficient | ±0.03%/℃ |
Output Start Time | ≤3.0S (120Vac input, Full load); ≤2.0S (220Vac input, Full load) |
Output Hold Time | ≥10mS(120Vac input, Full load); ≥20mS(220Vac input, Full load) |
Voltage Overshoot | <5.0% |
Input Voltage Range | 90VAC~264VAC |
Input Rated Voltage Range | 100VAC~240VAC |
Frequency Range | 47Hz~63Hz |
Efficiency | 91% |
Input Current | <2.2A |
Inrush Starting Current | <40A@300Vac Cold start |
Leakage Current | input to output less than 0.25mA |
Over Power Protection | 288~360W Swing machine (Testing method: Increase the output current until enabling the protection. Protection mode:Swing machine, Self-recovery after over-power released.) |
Over Voltage Protection | 28-29V Swing machine (Short circuit the Pin1-2 of U8, swing machine. Output recovery to normal after removing the short circuit) Note: Do not use external voltage. |
Over Current Protection | 12~15A Swing machine (Testing method: Increase the output current until enabling the protection. Protection mode:Swing machine, Self-recovery after over-current released.) |
Short Circuit Protection | It can be short circuited for a long time and automatically recover after the short circuit is eliminated. |
Operation Temperature And Humidity | -40℃~70℃; 20%~90%RH No condensing |
Storage Temperature And Humidity | -40℃~85℃; 5%~95%RH No condensing |
Security Standard | GB4943/EN60950 |
Dielectric Strength | Input—Output:3KVac/10mA; Input--Case:1.5KVac/10mA; Output---Case:0.5KVDC/10mA Time for each testing is 1min. |
Insulation Resistance | Input-Output: 100M ohms; Input-Case: 100M ohms; Output-Case: 100M ohms |
Electromagnetic Interference | EN55022 Class A |
Harmaonic Current | IEC61000-3-2 class A equipment requirements |
Electromagnetic interference Immunity | EN61000-4-2,4,5,6,8,11 ENV50204, class A heavy industry standard |
Design MTBF | 100,000Hrs AT 25℃, MIL-217 Method 2 Components Stress Method |
Dimensions (W*H*D) | 130.5*124*45mm |
Notes | If the specification is not specified, all specifications and parameters shall be measured at rated input, rated load and 25 C ambient temperature. Ripple noise test method: the use of a 12# twisted pair, while the terminal to parallel capacitance of 0.1uF and 10uF, measured at the scope of the oscilloscope 20MHz bandwidth. The power supply will be installed on the final equipment as a component, and the final equipment will still have to meet the EMC condition. |
E-mail:onv@onv.com.cn