Name:130W/24V Open Frame Power Supply(With Certification)

Model:GWS-BP130-24C

130W/24V Open Frame Power Supply(With Certification)

Name:
Information:
Email:
Telephone:
Company:
Code:

  Submit
  • Overview

  • Specification

  • Download

Product Name130W/24V Open Frame Power Supply(With Certification)
ModelGWS-BP130-24C
Group of Output1
DC Voltage24V
Output Current Range0-5.5A
Ripple noise0<Ta≤65℃:P-P≤100mV; -20≤Ta≤0℃:P-P≤100mV
Stabilized Voltage Precision @-20~65℃±1%
Line Regulation @-20~65℃±1%
Load Regulation @-20~65℃±1%
Temperature Coefficient @-20~65℃±0.03%/℃
Output Start Time @25℃≤3.0S (120Vac input, Full load); ≤2.0S (220Vac input, Full load)
Output Hold Time @25℃≥10mS(120Vac input, Full load); ≥20mS(220Vac input, Full load)
Voltage Overshoot @-20~65℃≤5%
Input Voltage Range90~264VAC
Input Rated Voltage Range100~240VAC
Frequency Range47Hz~63Hz
Starting Voltage @-20~65℃90Vac
Efficiency @ 25℃≥89%
Input Current @25℃<1.1A
Inrush Starting Current@25℃<40A@300Vac Cold start
Over power protection156~195W Swing machine (Testing method: Increase the output current until enabling the protection. Protection mode:Swing machine, Self-recovery after over-power released.)
Over voltage protection28-29V Swing machine (Short circuit the Pin1-2 of U8, swing machine. Output recovery to normal after removing the short circuit) Note: Do not use external voltage.
Over current protection6.5~8.13A Swing machine (Testing method: Increase the output current until enabling the protection. Protection mode:Swing machine, Self-recovery after over-current released.)
Short circuit protectionIt achieves the long-term short circuit by connecting a sufficient cross-sectional area copper cable (Length at 15cm±5cm) with power output port. Self-recovery to normal after removing the short circuit.
Operation Temperature and Humidity-20~65℃; 20%~95%RH
Storage Temperature and Humidity-40℃~85℃; 10%~95%RH non-condensing
LibrationFrequency range: 10 ~ 500Hz, Acceleration: 2G, Each sweep cycle 10min. Six sweeps along the X, Y, and Z axis
SurgeAcceleration: 20G, Duration time: 11mS, Three shocks along X, Y and Z axis
Altitude2000m
Security StandardGB4943/EN60950 ■Reference □Certification
Dielectric StrengthInput—Output:3KVac/10mA; Input--Case:1.5KVac/10mA; Output---Case:0.5KVDC/10mA Time for each testing is 1min.
Grounding TestTest Condition: 32A/2min; Ground bond: <0.1 ohms.
Leakage Current @25℃Input to GND ≤3.5mA; Input to output ≤0.25mA (Input 264Vac, 63Hz)
Insulation ResistanceInput-Output: 10M ohms; Input-Case: 10M ohms; Output-Case: 10M ohms;
Conducted InterferenceEN55022, EN55024, FCC PART 15 CLASS B
Radiated InterferenceEN55022, EN55024, FCC PART 15 CLASS B
Harmaonic currentEN61000-3-2 CLASS D
Conducted EmissionEN61000-4-6 Level3
Radiated EmissionEN61000-4-3 Leve3 criterion B
Power Frequency EmissionEN61000-4-8 Level3
Electrostatic EmissionEN61000-4-2 Level4 criterion B
EFTEN61000-4-4 Level4 criterion B
SurgeEN61000-4-5 Level4 criterion B
Dip and Interruption EN61000-4-11
Certification 3C.CE. FCC.EMI/EMC
Dimension / Weight173*65*25mm / 0.28kg
Top
  • E-mail:onv@onv.com.cn

  • WeChat